Comparison of the Photo-peak Efficiencies between the Experimental Data of 137Cs Radioactive Source with Monte Carlo (MC) Simulation Data

Pretam Kumar Das

Pabna University of Science &Technology, Department of Physics, Bangladesh.

Citation : Pretam Kumar Das, Comparison of the Photo-peak Efficiencies between the Experimental Data of 137Cs Radioactive Source with Monte Carlo (MC) Simulation Data International Journal of Advanced Research in Physical Science 2018, 5(10) : 24-28

Abstract

We have carried out an experiment of semiconductor detector (Germanium, Ge detector) using γ rays emitting source 137Cs at nuclear astrophysics laboratory of Okayama University in Japan. Now a days, Ge detectors are very important tools for γ ray's studies and nuclear spectroscopy research. We have measured the photo-peak efficiencies using the radioactive source 137Cs. We have created the Monte Carlo simulation with the help of GEometry ANd and Tracking (Geant4) successfully. The photo-peak efficiencies of MC simulation were calculated. We have compared our simulation data with the experimental data. We have found fair agreement between MC data and experimental data and it within 77%.